The mullion (or beam) of stick curtain wall is installed on the main structure first, and then the beam (or mullion) is installed.
Mullions and beams form a lattice, Panel materials are processed into unit components in the factory, then fixed on the frame lattice composed of mullion and beam. The load borne by the panel material unit components is transmitted to the main structure through mullions (or beams). The common form of the structure is that the mullions and crossbeams are installed on site to form a lattice and the panel material unit components are fixed on the skeleton, The panel material unit component is vertically connected to the column and horizontally connected to the beam and use sealant joint processing to prevent rain seepage and air infiltration. Standard products | Product standardization, serialized design, stable and reliable quality, can meet different requirements. |
Structure features | Positioning installation, distance pressing structure, uniform force on the glass plate; Plate floating connection structure, strong in-plane displacement absorption capacity. |
Water tightness Air tightness | Weather resistant sealant caulking, water tightness and air tightness can reach (GB/T15225-94) I class standard. |
Architectural effect | The facade is flat and simple |
Thermal insulation properties | Foam rod is used to fill the air cavity, weatherproof sealant is caulked, so that the heat transfer coefficient Uf of the frame can reach 1.7W/m2K. |
Standard products | It can be installed and disassembly freely |
Structure features | The glass is mainly subjected to wind pressure by the hook plate on the four sides. The design of structural sealant makes the structure have double safety protection function |
Architectural effect | The outer line of sight is concise and lively, with good permeability |
01 | Sound resistance Rw to 48 dB | 02 | Wind and water tightness to 1000 Pa (depending on design) |
03 | Column mounting | 04 | High thermal insulation (depending on design) |
05 | Beam installation | 06 | High glass weights to 300KG |
07 | View width 60mm | 08 | Different cover caps on the outside |
09 | Inside and outside color as desired |
NO. | Item | Quality standard |
1 | Column mounting | The elevation difference between two adjacent columns is less than or equal to 5mm. The distance difference between two adjacent columns is less than or equal to 2mm |
2 | Beam installation | The levelness deviation of the beam is less than or equal to 2mm, the horizontal elevation difference of the two adjacent beams is less than or equal to 1mm, the distance deviation of the two adjacent beams is less than or equal to 2mm, and the height difference of the main beam within the same height is less than or equal to 5mm. |
Curtain wall with lighting function requirements, the transmittance reduction factor should not be less than 0.45. Curtain wall with color discrimination requirements, its color perspective index should not be lower than Ra80 The curtain wall shall be able to support its own weight and the weight of various accessories in the design, and can be reliably transferred to the main structure The maximum deflection of the horizontal stressed member within the span at both ends of a single panel under standard dead weight should not exceed 1/500 of the span at both ends of the panel, and not exceed 3mm Curtain wall tempered glass should be processed by hot dip. Secondary heat treatment, soaking heat treatment, detonation treatment, "after treatment can be less than 1/1000 of the self-explosion rate" is commonly used in engineering
Site installation
Paste on site